4-inch Low-pressure High Rejection Membrane Elements
Thumb 1

4-inch Low-pressure High Rejection Membrane Elements

JOZZON's 4-inch low-pressure membrane elements deliver 99%-99.5% salt rejection, ensuring superior permeate quality for demanding commercial applications. Featuring a rugged fiberglass wound shell, these elements offer excellent pressure resistance and long-term stability.

99%-99.5%
Salt Rejection
150 psi
Operating Pressure
90
Effective Membrane Area Ft2
Applied Industries
Ideal for Systems Requiring High-purity Water, Including Laboratories, Medical Facilities, and Beverage Production

Product Overview

JOZZON's 4-inch low-pressure high-rejection membrane elements, achieving 99%-99.5% salt rejection, are engineered for applications where permeate water quality is the highest priority. From laboratory ultrapure water systems to medical facilities and beverage production lines, these elements can be flexibly configured to meet various requirements, including high desalination, stable operation, or compact system design.

All elements feature a rugged fiberglass wound shell, offering better pressure resistance than traditional glued or taped alternatives. This robust construction prevents membrane telescoping under fluctuating operating conditions, delivers a longer service life with fewer failure risks, and maintains consistent rejection performance over time. The high rejection rate significantly extends the regeneration cycles of downstream DI or EDI systems, reducing overall operating costs.

Whether you are designing a hospital central water system, a food and beverage processing unit, or a laboratory RO unit, JOZZON's 4-inch high-rejection low-pressure elements provide the perfect balance of water quality, durability, and energy efficiency.

Features & Benefit

1.High Water Flux

Optimized membrane structure and hydrophilic modification deliver higher flow at same pressure, reducing membrane count and initial investment.

2.Excellent Salt Rejection

99%-99.5% salt rejection effectively removes salts and contaminants, ensuring permeate quality and extending downstream system regeneration cycles.

3.Reduced Energy Consumption

Low-pressure drop design and high-hydrophilicity materials lower operating pressure by 15-30%, cutting electricity costs and enabling green production.

4.Stable Long-Term Performance

Excellent resistance to chemical degradation and compaction ensures slow flux decline, with a 3-5+ year service life and fewer cleaning/replacement needs.

5.Wide Feed Water Compatibility

Fouling-resistant, wide-channel design adapts to various water types (groundwater, reclaimed water, etc.), resisting fouling and reducing pretreatment requirements.

6.Easy System Integration

Standard industrial dimensions compatible with mainstream membrane housings and pipes enable quick drop-in replacement, short commissioning time, and easy maintenance.

Stable Long-Term Performance

Available Models

Membrane Element Model

Effective Membrane Area

ft2 (m2)

Water Production Flow Rate

GPD (m³/d)

Stable Desalination Rate

(%)

Minimum Desalination Rate

(%)

JRW-4040-HR

90 (8.4)

2300 (8.7)

99.5

99.0

Extreme Usage Conditions

Maximum Operating Pressure 600psi (4.14 MPa)
Maximum Influent Flow Rate 16gpm (3.6 m³/h)
Maximum Inlet Water Temperature 45℃
Maximum Influent SDI15 5
Influent Free Chlorine Concentration < 0.1 ppm
Influent pH Range During Continuous Operation 2~12
pH Range of Influent During Chemical Cleaning (Short-term 30-minute Period) 1~13
Maximum Pressure Drop of a Single Membrane Element 15psi (0.1Mpa)

Test Conditions

Test Pressure 150psi (1.03Mpa)
Test Solution Temperature 25℃
Test Solution Concentration (NaCl) 1500ppm
pH Value of The Test Solution 7.5
Single Membrane Element Recovery Rate 15%

Membrane Element Size

The units in the diagram are millimeters (inches).

A=1016.0mm (40"), B=99.7mm (3.9")
C=19.1mm (0.75"), D=26.7mm (1.05")
4040 High Rejection Reverse Osmosis Membrane