S-resistant Household Memabrane
JOZZON household anti-fouling reverse osmosis membranes are primarily used in home water purification applications in areas with poor water quality.
Due to excellent anti-fouling capabilities, they are particularly suitable for treating water sources with high levels of pollutants such as organic matter and microorganisms.
Available Documentations
Request a Commercial Quote
Applied Industries
Households in areas with poor water quality: This is its core application scenario. The product effectively removes organic matter, heavy metals, viruses, and other contaminants from water, making it ideal for solving drinking water safety issues in areas with severe water pollution.
Families with sensitive water consumption: Meeting the needs of mothers and infants, the elderly, and families with high-quality requirements for the taste of brewed drinks (such as formula and coffee), ensuring pure, odorless water.
Domestic and commercial direct drinking water equipment manufacturers: As a core filtration element, it is widely integrated into household kitchen water purifiers, office water purifiers, and commercial water purifiers.
Specific overseas residential water purification markets : jozzons products have successfully entered the residential water purification markets of Southeast Asia, the UK, the US, and other countries and regions, competing with international brands based on their performance advantages.

Features & Benefit
JOZZON's fouling-resistant household membrane elements utilize JOZZON's unique fouling-resistant membrane sheets and new winding technology, ensuring high water flux while providing enhanced resistance to scaling and fouling. These membrane elements are designed to replace traditional household membrane elements and offer longer service life and higher water flux in mountainous and mining areas.
Available Models
|
Membrane Element Model |
Stable Desalination Rate (%) |
Water Production Flow Rate GPD (m³/d) |
Test Conditions |
||
|---|---|---|---|---|---|
|
Test pressure psi (MPa) |
Test solution concentration (ppm) |
Recovery rate (%)Â |
|||
|
JRW-1812-60-FR |
97.0 |
60 (0.23) |
60(0.4) |
500, NaCl |
15 |
|
JRW-1812-80-FR |
97.0 |
80 (0.3) |
60(0.4) |
500, NaCl |
15 |
Note: Component models not mentioned (membrane performance, appearance dimensions) can be customized according to order quantity.
Extreme Usage Conditions
| Maximum Operating Pressure | 300psi (2.07MPa) |
| Maximum Inlet Water Temperature | 45℃ |
| Maximum Influent SDI15 | 5 |
| Influent Free Chlorine Concentration | < 0.1 ppm |
| Influent ph Range During Continuous Operation | 2~12 |
| ph Range of Influent During Chemical Cleaning (Short-term 30-minute Period) | 1~13 |
| Maximum Pressure Drop of a Single Membrane Element | 10psi (0.07Mpa) |
Test Conditions
| Test Solution Temperature | 25℃ |
| Test Solution ph Value | 7.5 |
Membrane Element Size
The units in the diagram are millimeters (inches).